Electrical wire

Southwire 14/2NM-WGX25

Type NM-B Sheathed Cable

14 AWG, 25 ft L, White Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  25′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

Electrical wire

Southwire 14/3NM-WGX25

Type NM-B Sheathed Cable

14 AWG, 25 ft L, White Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  3
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  25′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
  •  
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

Electrical wire

Southwire 14/2NM-WGX50

Type NM-B Sheathed Cable

14 AWG, 50 ft L, White Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  50′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

Electrical wire

Romex 14/2UF-WGX50

Type UF-B Building Wire

14 AWG, 50 ft L, Gray Nylon Sheath

Product Overview

Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  50′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

6998728

Southwire 14/3NM-WGX50

Type NM-B Sheathed Cable

14 AWG, 50 ft L, White Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  3
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  50′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

8970436

Southwire 14/2NM-WGX100

Type NM-B Sheathed Cable

14 AWG, 100 ft L, White Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  100′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

6963318

Romex 14/2UF-WGX100

Type UF-B Building Wire

14 AWG, 100 ft L, Gray Nylon Sheath

Product Overview

Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  100′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

8153819

Southwire 14/2NM-WGX250

Type NM-B Sheathed Cable

14 AWG, 250 ft L, White Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  14
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  250′
  • Strands:  1
  • Amperage Rating:  15
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

8970444

Southwire 12/2NM-WGX25

Type NM-B Sheathed Cable

12 AWG, 25 ft L, Yellow Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  12
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  25′
  • Strands:  1
  • Amperage Rating:  20
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

4460663

Southwire Armorlite 68580021

Metal Clad Armored Cable

12 AWG, 25 ft L, Aluminum Armor

Product Overview

Pre-installed conductors within an overall protective metallic interlocked armor. 45% lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 deg C dry, 75 deg C wet at 600 V. Conductor insulation is flame retardant, heat-resistant PVC with flame, oil- and gasoline-resistant nylon jacket. General applications such as branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential construction/facilities, power, lighting, control and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray and as aerial cable on a messenger. UL classified 1, 2 and 3 hrs through penetration firestop systems W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065 and C-A-J-4066. UL listed.

Product Details

  • Cable Size: 12 AWG
  • Conductor Insulation: THHN/THWN
  • Conductor Material: Copper
  • Current Rating: 20 A
  • Includes: Aluminum Armor
  • Number of Conductors: 2
  • Operating Temperature: 90 deg C
  • Sheath Diameter: 0527 in
  • Stranded/ Solid: Solid
  • Type: Metal Clad
  • Voltage Rating: 600 V
  • Fished or embedded in plaster
  • Concealed or exposed installations
  • Environmental air-handling spaces per NEC 300.22©
  • As aerial cable on a messenger
  • Installation in cable tray and approved raceways
  • Lightweight aluminum interlocked armor

8970451

Southwire 12/2NM-WGX50

Type NM-B Sheathed Cable

12 AWG, 50 ft L, Yellow Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  12
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  50′
  • Strands:  1
  • Amperage Rating:  20
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

6431845

Romex 12/2UF-WGX50

Type UF-B Building Wire

12 AWG, 50 ft L, Gray Nylon Sheath

Product Overview

Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.

Product Details

  • Conductor Size:  12
  • Number of Conductors:  2
  • Conductor Material:  Copper
  • Length:  50′
  • Strands:  1
  • Amperage Rating:  20
  • Voltage Rating:  600
  • Southwire Type UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire
  • Copper conductors are annealed (soft) copper, solid or compressed stranded
  • Phase conductors are PVC insulated, nylon jacketed, color coded for identification purposes
  • Jacketed with sunlight, moisture and fungus-resistant gray PVC
  • Underground feeder and branch circuit cable

8970469

Southwire 12/2NM-WGX100

Type NM-B Sheathed Cable

12 AWG, 100 ft L, Yellow Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  12
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  100′
  • Strands:  1
  • Amperage Rating:  20
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

6432066

Romex 12/2UF-WGX100

Type UF-B Building Wire

12 AWG, 100 ft L, Gray Nylon Sheath

Product Overview

Type THHN insulation, rated 90 deg C, 600 V. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame-retardant, moisture, fungus and corrosion-resistant. Sunlight-resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL listed.

Product Details

  • Conductor Insulation: PVC
  • Conductor Material: Copper
  • Current Rating: 20 A
  • Insulation Material: PVC
  • Jacket Material: Nylon
  • Length: 100 ft
  • Number of Conductors: 2
  • Operating Temperature: 90 deg C
  • Resistance: Fungus Moisture Sunlight
  • Sheath Color: Gray
  • Sheath Material: Nylon
  • Strands per Conductor: 2
  • Type: Type UF-B
  • Voltage Rating: 600 V
  • Wire Size: 12 AWG
  • Southwire Type UF-B cable is manufactured as a 2 or 3 conductor cable, with or without a ground wire
  • Copper conductors are annealed (soft) copper, solid or compressed stranded
  • Phase conductors are PVC insulated, nylon jacketed, color coded for identification purposes
  • Jacketed with sunlight, moisture and fungus-resistant gray PVC
  • Underground feeder and branch circuit cable

 

8153827

Southwire 12/2NM-WGX250

Type NM-B Sheathed Cable

12 AWG, 250 ft L, Yellow Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  12
  • Number of Conductors:  2
  • Conductor Material:  Copper/ASTM B3 and B8
  • Length:  250′
  • Strands:  1
  • Amperage Rating:  20
  • Voltage Rating:  600
     
    Usage:
    For Both Exposed and Concealed Work in Normally Dry Locations

Electrical wire

Southwire 10/2NM-WGX25

Type NM-B Sheathed Cable

10 AWG, 25 ft L, Orange Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  10
  • Number of Conductors:  2
  • Conductor Material:  Copper
  • Length:  25′
  • Strands:  1
  • Amperage Rating:  30
  • Voltage Rating:  600

Electrical wire

Southwire 10/2NM-WGX50

Type NM-B Sheathed Cable

10 AWG, 50 ft L, Orange Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  10
  • Number of Conductors:  2
  • Conductor Material:  Copper
  • Length:  50′
  • Strands:  1
  • Amperage Rating:  30
  • Voltage Rating:  600

Electrical wire

Southwire 10/2NM-WGX100

Type NM-B Sheathed Cable

10 AWG, 100 ft L, Orange Nylon Sheath

Product Overview

Inner conductors are type THHN, rated 90 deg C, 600 V. Solid strands. Outer jacket is PVC, rated at 75 deg C. Amp rating of the product is limited to that for 60 deg C rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL listed.

Product Details

  • Conductor Size:  10
  • Number of Conductors:  2
  • Conductor Material:  Copper
  • Length:  100′
  • Strands:  1
  • Amperage Rating:  30
  • Voltage Rating:  600